• JTC Jet Technology Centre
    Specialists in Accessory Overhaul


  Condensing Impulse Type Steam Turbine 7700 kWe SOCIETE RATEAU


Zoom Zoom Image
Product Catalogue-1
More Information
  TECHNICAL SPECIFICATION
Capacity : 7700 kWe
Inlet Steam Pressure, Temperature : 57 ata, 480 C
Intermediate Steam Extraction :
Exit Steam Pressure : 0,1 kg/cm2 (abs)
Back Pressure :
Steam Turbine Revolution : 7500 rpm/1500 rpm
Voltage : 6300 V
Frequency : 50 Hz
Manufacturing Year : 1969
Hours Of Operation : out of operation in 2001

  Condensing Impulse Type Steam Turbine 7700 kWe   - Image Gallery

  Condensing Impulse Type Steam Turbine 7700 kWe   Details

Turbo Generator Set

 

- SOCIETE RATEAU, Type TH 457-480 multi stage condensing impulse steam turbine.

- MAAG, type GN 70 speed reduction gear.

- ALSTHOM, 7,7MW A.C. generator.

 

Backpressure Steam Turbine

Type  : TH 457-480

Turbine-to- gear coupling type : MAAG ZNS 6

Gear-to-Generator coupling type : MAAG ZNS 9

 

Speed reduction gear

Type  : MAAG GN 70

Input speed : 7540 rpm

Output speed : 1500 rpm

 

Generator

 Alsthon Belfort 1969

 Type  : RNV 144-125

 No : 409351

Voltage : 6300V

Current : 882 A

Speed of Rotation : 1500 r.p.m

KVA : 9625

Cos(fi) : 0,8

Frequency : 50 Hz

Insu Cl. : B

Protection : Enclosed

Excitation : V 47 A 639

 

Performance data

Steam inlet pressure : 57 ata

Steam inlet temperature : 480 Deg. C 

Exhaust pressure : 0,1 kg/cm2 (abs)

Throttle steam flow : 36000 kg/h

Total kW rating :7700 kW

 

Speed of rotation : 7500 rpm

Max. Continious speed of rotation : 7875 rpm

Trip speed  : 8250 rpm

 

Lube Oil Filter

Make &type : Rellumix 32C 400

Oil flow rate : 500 l/min

Pressure drops : 0,5 bars

Filtering efficiency : 20 microns

Oil grade : 50 C No.3 mineral

Service pressure : 5 bars

 

Governing & safety oil filter

Make &type  : Rellumix D7C 400

Oil flow rate : 100 l/min

Pressure drops : 0,35 bars

Filtering efficiency : 20 microns

Oil grade : 50C No.3 mineral

Service pressure : 12,5 bar